| Customization: | Available |
|---|---|
| After-sales Service: | Video Intallment |
| Power Supply: | 220-380V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
WBE Weibang Ultraviolet Weathering Aging Test Chamber:
The UV test can simulate the damage caused by sunlight, rain and dew. It uses fluorescent UV lamps to simulate the effect of sunlight exposure and uses condensation moisture to simulate rain and dew. The tested materials are placed in a cycle of alternating light and moisture at a certain temperature for testing. The UV test can reproduce the damage that occurs outdoors in months or years within days or weeks. The types of damage include: fading, discoloration, loss of gloss, powdering, cracking, clouding, bubbling, embrittlement, strength reduction and oxidation. UV test data can help you choose new materials and evaluate how changes in formulations affect the durability of new products. It is widely used in coatings, inks, paints, resins, plastics, rubber, printing and packaging, aluminum profiles, adhesives, automotive and motorcycle industries, cosmetics, metals, electronics, electroplating, medicine, etc.
Festure:
Test Standard:
GB/T16585-1996,GB/T16422.3-2014,ISO4892-3:2006,GB/T14522-93......
Application:
Military equipment, electronic devices, instruments and meters, aerospace products, battery packs, energy storage cabinets, engines
Packing & Shipping
Specification
| UV ultraviolet aging test chamber | ||
| Model | WBE-UV-3 | |
| Product Type | Tower type | |
| Inner box dimensions mm (W=D*H) | 1140 * 400 * 500 | |
| External dimensions mm (W=D*H) | 1340 * 630 * 1400 | |
| Light source | Lamp tube wavelength (Choose one of them) |
UVA-340, band 315-400nm, irradiance 0.35-1.2W/m ² |
| UVA-351, band 351-400nm, irradiance 0.35-12W/m ² | ||
| UVB-313, 280-315nm, irradiance 0.35-1.2W/m ² | ||
| Number of tubes | cheep | |
| Lamp tube power | 40W per tube | |
| Lamp tube brand | American Q-LAB/ Domestic (WBE) | |
| Lamp tube lifespan | About 600 hours | |
| Set up power | Basic Functions | Temperature, light, spray, cold season |
| Optional features | Irradiance display: With handheld or mounting irradiance meter (optional) | |
| Illumination adjustment: Dimming system | ||
| Technical indicators | Blackboard temperature range | 50 ºC ~ 63 ºC |
| Cold weather test temperature | 50C±3ºC | |
| Condensation humidity range | ≥75%RH | |
| Temperature uniformity | + / - 3 ºC | |
| Temperature fluctuation | Plus or minus 0.5 ºC | |
| Keep the sample away from the lamp tube torch | 55mm | |
| Distance from the center inside the lamp tube | 65~70mm | |
| Tower standard test piece size | 75×150mm 42 pieces | |
| Test time | Adjustable from 1 to 9999H.M.S | |
| Safety protection system | Line sequence protection, leakage protection, over-temperature protection, anomaly protection | |
| Equipment Operating conditions | Power 220V: Frequency 50HZ; Power: 4.5KW | |
| Environmental conditions | Temperature 5 ° C to 30 ° C; Relative humidity ≤85%RH | |
| Inner liner material | SUS304 stainless steel plate | |
| Outer box material | SUS304 unribbed/coated | |
| Control system | Siemens touchscreen and PLC control | |
| Main components | French Snade and Japanese Omron | |
| Irradiation sensing | Imported intelligent vehicle photo sensor repair, 0-5V signal output | |
| Safety protection system | Sequence protection, leakage protection, over-temperature protection, anomaly protection | |